Valcom V-2920 User Manual

Browse online or download User Manual for Door intercom systems Valcom V-2920. valcom one-way paging system design/information general

  • Download
  • Add to my manuals
  • Print
  • Page
    / 13
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
VSP – One-Way Paging
Issue 13
1 947100
VALCOM ONE-WAY PAGING
SYSTEM DESIGN/INFORMATION
GENERAL
These instructions provide the basic information
required to properly install a One-Way paging system
manufactured by Valcom, Inc.
Valcom One-Way Paging Equipment may be used
with any 1A2, Electronic Key, PABX Telephone
Systems, or with one or more dedicated single line
telephones.
SYSTEM OVERVIEW
Purpose
Provides telephone accessed single or multizone
paging.
Applications
1A2
Electronic Key Systems
PABX
Stand alone systems
VALCOM
ONE-WAY
CONTROL
UNIT
ONE-WAY
SPEAKER
ASSEMBLY
POWER
SUPPLY
TELEPHONE
SYSTEM
ONE-WAY PAGING SYSTEM BLOCK DIAGRAM
FIGURE 1
Features
1, 3, 6, 9, 19, 20 and 36 zone page units
available.
One-way all call to all speakers available.
Volume controls and amplifiers in each speaker.
No high power amplifier required.
Standard 22 or 24 AWG twisted pair telephone
wire used for speakers.
Existing house cables or feed cables may be used
without introducing crosstalk.
Access Methods
1A2 line button (line card not required on most
units).
Electronic Key System line button (C. O. circuit
required).
PABX loop trunk port (trunk circuit required).
Page port.
Station level access available (with appropriate
adapter).
Stand alone with dedicated single line sets.
Capacity
All units are one talkpath and one link.
V-1094A, 1 zone (page port access only).
V-9937, 1 zone.
V-1101A, 1 zone.
V-2000, 1 zone with an integrated power supply.
V-2001A, 1 zone with an integrated power
supply, override capabilities and featuring two
integrated tone generators for night ringing and
time clock tones.
V-2003A, 3 zones with all call, background
music capabilities, override capabilities, two
integrated tones for night ringing and time clock
signaling plus integrated power supply.
Page view 0
1 2 3 4 5 6 ... 12 13

Summary of Contents

Page 1 - SYSTEM DESIGN/INFORMATION

VSP – One-Way PagingIssue 131 947100VALCOM ONE-WAY PAGINGSYSTEM DESIGN/INFORMATIONGENERALThese instructions provide the basic informationrequired to p

Page 2 - Environment

10 947100• Jobs requiring explosion-proof systems are easily accommodated.• Amplified one-way speakers can interface 70 volt systems without changin

Page 3 - Speaker Power Requirements

11 947100Table 10 - Valcom One-Way Page Control/Interface Feature ChartModel # V-1094A V-9937 V-1101A V-2000 V-2001A V-2003A V-2006A V-1109RTVA V-119R

Page 4 - SYSTEM DESIGN

12 947100Table 11 - Distributed Amplified Speaker Power Wire Run GuideNumber of Speakers or Horns per Power Run Wire Run Length (feet)30 WattHorn15 Wa

Page 5 - Station level Paging

13 947100Table 12 - Twisting Wire Pairs To Increase Effective Wire GaugeTwisting 2 or more pairs of wire together will increase the effective wire gau

Page 6 - SYSTEM INSTALLATION

2 947100• V-2006A, 6 zones with all call, up to 3 groupcalls, override capabilities, background musiccapabilities, two integrated tone generators for

Page 7 - Volume Adjustments

3 947100Speaker Power RequirementsTable 2Speaker PowerRequirementsVPUV-1010C, V-1011BB,V-1011MR,V-1012BB, V-1012MR,V-1013A-BK, V-1013A-W,V-1013A-GY V-

Page 8 - PROBLEM SOLVERS

4 947100SYSTEM DESIGN1A2, Dedicated Single Line Set,E-Key, or PABX PagingTelephoneSystem C.O.Loop StartTrunk PortValcom PageControl UnitTRAdditional

Page 9 - 25/70/100 VOLT PAGING

5 947100for guidelines concerning maximum allowabledistances for power runs.3. When the paging system is in several buildingsor on several floors o

Page 10

6 947100A default time is available when using the "openloop" disconnect on the V-9940 (up to 64 seconds).An additional feature of the V-994

Page 11 - 11 947100

7 947100Table 6 - Horn Spacing/CoverageLocation 5 Watt 15 Watt 30 WattQuiet50-65db110'(12,000 ft2)N/A N/AModerate65-80Db80'(6,400ft2)N/A N/A

Page 12

8 947100The master control may then be used to change thevolume of the entire system. If background music isbeing supplied, the background music leve

Page 13

9 947100ENHANCEMENT TO EXISTING25/70/100 VOLT PAGINGSYSTEMSUsing a Valcom PageControl/Interface with a CentralAmplifierTypically a zone from a one-way