Valcom ONE-WAY PAGING SYSTEM User Manual

Browse online or download User Manual for Door intercom systems Valcom ONE-WAY PAGING SYSTEM. VALCOM ONE-WAY PAGING SYSTEM DESIGN/INFORMATION

  • Download
  • Add to my manuals
  • Print
  • Page
    / 11
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Issue 15
1 947100
VALCOM ONE-WAY PAGING
SYSTEM DESIGN/INFORMATION
GENERAL
These instructions provide the basic information
required to properly install a One-Way paging
system manufactured by Valcom, Inc. Valcom
One-Way Paging Equipment may be used with
any 1A2, Electronic Key, PABX Telephone
Systems, or with one or more dedicated single
line telephone sets.
SYSTEM OVERVIEW
Purpose
Provides telephone accessed single or multizone
paging.
Applications
Electronic Key Systems
PABX
Stand alone systems
1A2
VALCOM
ONE-WAY
CONTROL
UNIT
ONE-WAY
SPEAKER
A
SSEM BLY
POWER
SUPPLY
TELEPHONE
SYSTEM
ONE-WAY PAGING SYSTEM BLOCK DIAGRAM
FIGURE 1
Features
1, 3, 6, 9, and 24 (expandable with V-2925A
in 24 zone increments for up to 96) zone page
control units available.
One-way all call to all speakers available.
Volume controls and amplifiers in each
speaker.
No high power amplifier required.
Standard CAT 3, 5, 5E twisted pair cable
(typically 22 or 24 AWG) is used for speakers.
Existing twisted pair house cables / feed
cables may be used without introducing
crosstalk.
See Multi-Path Information for systems up to
360 zones.
Access Methods
Electronic Key System line button (C. O.
circuit required).
PABX loop trunk port (trunk circuit required).
Page port (some with N.O. CC).
Station level access available (with
appropriate adapter).
Stand alone with dedicated single line sets.
1A2 line button (line card required on most
units).
Capacity
All units are one talkpath and one link.
V-1094A, 1 zone (page port access only).
V-2000A, 1 zone with an integrated power
supply, background music input.
V-2001A, 1 zone with an integrated power
supply, background music capabilities and
override capabilities, and featuring two
integrated tone generators for night ringing
and time clock tones.
V-2003A, 3 zones with all call, background
music capabilities, override capabilities, two
integrated tones for night ringing and time
clock signaling plus integrated power supply.
V-2006A, 6 zones with all call, up to 3 group
calls, override capabilities, background music
capabilities, two integrated tone generators
for night ringing and time clock tones plus
integrated power supply.
V-2924A, 24 zones with all call, background
music capabilities.
V-9937, 1 zone, page port access.
V-1109RTVA, 9 zones with all call,
background music capabilities (no station or
page port access).
Each of the units listed above will drive up to 40
Valcom one-way amplified speaker assemblies
per zone (150 on V-1094A, V-9937, V-2000A,
V-2001A, V-2003A and V-2006A). Additional
speakers may be added to a zone by using a
V-1094A. Each V-1094A allows the addition of
150 more amplified speaker assemblies to that
zone.
Page view 0
1 2 3 4 5 6 ... 10 11

Summary of Contents

Page 1 - SYSTEM DESIGN/INFORMATION

Issue 15 1 947100 VALCOM ONE-WAY PAGING SYSTEM DESIGN/INFORMATION GENERAL These instructions provide the basic information required to properl

Page 2

10 947100 Table 7 Ceiling Speaker Support Ring Bridge Backbox Bridge/Backbox Combo Flamex® Metal V-1010C - V-9904M-5 V-9915M-5* - - X V-102

Page 3 - SYSTEM DESIGN

11 947100 Table 8 – Valcom One-Way Page Control/Interface Feature Chart Model # V-1094A V-2000A V-2001A V-2003A V-2006A V-1109RTVA V-2924A/ V-29

Page 4 - Station level Paging

2 947100 VoIP (Voice-over-Internet-Protocol) Adapters  Valcom’s VoIP adapters provide loudspeaker paging through the client’s LAN/WAN.  VIP-801

Page 5 - SYSTEM INSTALLATION

3 947100 One-Way Self-Amplified Speaker Styles Valcom One-Way Self-Amplified Speakers are available in many styles to accommodate virtually any env

Page 6 - Speaker Cabling

4 947100 Table 2 - Valcom Power Supplies There are several cases when more than one power supply will be required: 1. When the power r

Page 7 - TECHNICAL ASSISTANCE

5 947100 With the V-9940 and V-9970, this line condition may be quiet line sensing, a strict "time out" (disconnects after a selected per

Page 8 - 25/70/100 VOLT PAGING

6 947100 Track Style Speakers: The 1 watt version will cover an area up to 600 sq. feet. These speakers should be spaced approximately 20 feet apa

Page 9

7 947100 Table 6 – Number of Speakers per Power Run (CAT 3/5/5E/6, 22 & 24AWG) Bridges and Backboxes Ceiling speaker bridges provide support

Page 10

8 947100 PROBLEM SOLVERS Automatic Volume Control The V-9933A Noise Sensing Volume Control monitors the noise level fluctuations in an area by util

Page 11

9 947100 ADVANTAGES OF DISTRIBUTED AMPLIFIED SYSTEMS  Low voltage, therefore existing telephone cable (Class 2 wiring) can be used to eliminate

Comments to this Manuals

No comments